Thermo Scientific™ Slide-A-Lyzer™ Dialysis Cassettes, 3.5K MWCO – Each of 1

CHF 266.50

Remove salts and contaminants, and maximize sample recovery using this semi-permeable membrane with a 3,500-Dalton protein MW cut-off (MWCO) cassette that is easier to use than traditional dialysis tubing.

Description

Slide-A-Lyzer Dialysis Cassettes (3.5K MWCO) facilitate simple and effective removal of salts and small contaminants from proteins and other macromolecules larger than 3,500 Daltons. They can be used for a wide range of applications including low-molecular weight contaminant removal, buffer exchange, desalting, equilibrium dialysis, and sample concentration.

Liquid samples are easily added and removed by penetrating the self-sealing gasket with a hypodermic needle attached to a syringe. No knots, clips, or caps are needed to seal the units and prevent leaking and sample loss during the dialysis procedure. Slide-A-Lyzer Dialysis Cassettes are constructed from two sheets of low-binding, regenerated-cellulose dialysis membrane that are hermetically sealed on either side of a silicone-like gasket inside an inert plastic frame. The membrane and cassette materials are compatible with most common laboratory chemicals and buffers.

Features of Slide-A-Lyzer Dialysis Cassettes:
Easy to use—no knots or clamps are needed; just inject sample into cassette and begin dialysis.
Fast dialysis—flat cassette chamber with two membranes provides high surface area-to-volume ratio that maximizes diffusion rate compared to cylindrical dialysis tubing.
High recovery—rectangular cassette design maximizes recovery of entire sample volume from any one of the four corner injection ports.
Four cassette sizes—select the cassette that best suits your sample volume (0.5 to 30 mL).
Color-coded—pink cassette frame specifies cassettes with the 3,500 MW pore size membrane.

Membrane specifications:
Composition: regenerated cellulose synthesized by the viscose method.
Thickness: 0.9 to 1.2 mil (22.5 to 30 μm).
Hydration time required before use: 2 minutes.
Glycerol content: none.
Sulfur content: 0.1–0.15%.
Heavy metals content: trace.

Volume ranges:
• 0.5 mL = 0.1 to 0.5 mL.
• 3 mL = 0.5 to 3 mL.
• 12 mL = 3 to 12 mL.
• 30 mL = 12 to 30 mL.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Specifications

Store at room temperature
Cellulose Membrane, Dialysis
3.5 kDa
1 Kit (8 Cassettes)
Buffer Exchange, Protein
Cassette
Slide-A-Lyzer™
12 mL